PPG phases out SIGMACOVER 380, replaced by a new grade
Product change is the most common kind of news in this trade and the easiest to get wrong. The manufacturer issues a notice, the salesperson forwards it, the client replies "noted" in the group chat, and the site carries on with old habits. At acceptance you discover the overcoating interval is wrong or the certificate scope does not cover the work, and only then does it become clear this was never just a name change.
Break the change into four questions: what changed, why, what it means for your project, and what to do now.
1. What changed
SIGMACOVER 380 is a general-purpose pure epoxy primer, widely used in marine and industrial protection, particularly in ballast tanks and cargo holds where a versatile scheme is needed. It is being phased out, replaced by SIGMAPRIME 700 HSV, a general-purpose high-solids epoxy.
High solids is the key difference. For the same dry film thickness, a high-solids product needs a thinner wet film, emits less VOC and can reach greater thickness in a single coat. That affects consumption calculations, coat design and ventilation requirements.
In product terms, 700 HSV is an upgrade within the pure epoxy family, not a cross-family replacement such as an inorganic zinc or a polyurethane. That matters: the primer type is unchanged, so compatibility with existing intermediate and topcoat most likely still holds, but it must be confirmed against the new data sheet.
2. Why manufacturers make this kind of change
Replacing a pure epoxy primer with a high-solids product usually has several drivers: tightening VOC regulation that restricts solvent-borne products in more ports and yards; application efficiency, since high solids can reduce the number of coats; and portfolio consolidation, folding several similar grades into one.
For the user, only the first is a hard constraint; the other two are neutral or even favourable. VOC limits deserve separate attention: if the yard or project location has already tightened requirements, this change solves a problem in advance rather than creating one.
Note that the specific phase-out timetable and local supply arrangements are set by PPG's local organisations and are not globally synchronised. So the first task is to establish local stock and cut-off dates, not to plan from the general wording of the notice.
3. What it means for the user
One product covering more compartments: beyond ballast tanks, 700 HSV also holds cargo oil tank and crude oil tank approvals, reducing the number of grades selected per compartment. For a yard, one fewer grade means one fewer changeover and cleaning, and one less chance of misapplication.
The scheme must be re-checked: existing schemes were written around 380. With 700 HSV the compatibility of intermediate and topcoat, the maximum overcoating interval and whether sweep blasting is still required all need confirming against the new data sheet.
Consumption will change: high solids means less wet paint for the same dry thickness, so material cost should fall in theory. But if the original design specified a number of coats for 380, the coat count may need redesigning rather than simply ordering the same quantity.
Application habits need adjusting: high-solids products are more viscous, so airless spray nozzle, pressure and thinning ratio all change. Spraying with the old parameters risks dry spray, orange peel or uneven thickness.
4. What to do if you are using 380 now
Handle it in three cases rather than applying one rule.
Work in progress: do not simply put 700 HSV into the same coat. Re-verify the scheme and overcoating intervals against the new data sheet, and run a small trial area if needed to confirm intercoat adhesion and appearance. Completed areas stay as they are, but subsequent coats use the new parameters.
Contract signed, work not started: this is where documentation matters most. Grade, unit price and delivery schedule all need a change confirmation, ideally fixed through a technical clarification or supplementary agreement, to avoid argument at settlement.
Design stage: design directly on the new parameters and record the reason the original specified 380, so you can answer the owner or shipowner later.
One case is often overlooked: stock. If you hold 380, confirm batch numbers, shelf life and whether it can still be used on the original project. Using old batches on new projects, or mixing old and new, is the most common source of trouble at acceptance.
5. My advice
First, ask for three documents: the new product data sheet, the phase-out notice with the local timetable, and a new-versus-old comparison. The third is the most important and the least likely to be offered — ask for it.
Second, map the exposure: how many projects are in progress, how many signed but not started, how much stock is held, and which compartments are affected by the certification change. Only with that table do you know the size of the issue.
Third, do not let the change become an excuse for a price increase or a silent downgrade. Some suppliers use product changes to reprice; comparing the parameters tells you whether it is justified. If the new product has higher solids and greater single-coat thickness, a rise per litre is understandable, but cost per square metre should be flat or lower.
The change itself is not the problem; information asymmetry is. Put the parameters side by side and most disputes disappear.