C3, C4, C5: how corrosivity categories actually get assigned
The C1–CX categories in ISO 12944 come from annual mass loss of steel coupons, not from industry. Inside one petrochemical unit, a tank roof can be C5 while the shaded base is C3 — the base sees no rain and accumulates no salt.
1. What the categories mean in practice
C2 is heated interior and dry warehouse, very low mass loss, ordinary alkyd is enough. C3 is urban and general industrial atmosphere, humid plant interiors, moderate corrosion. C4 is chemical plant, mildly saline coastal, and de-icing salt environments.
C5 splits into C5-I (industrial, acid gases and particulates) and C5-M (marine, chloride). CX covers offshore platforms and tropical high-salinity industrial zones. Immersion is a separate scale, Im1–Im4.
2. Assign on site, not from a table
Look at three things: whether the surface stays wet (condensation, steam, spray); whether there is salt (distance to sea, de-icing salt, process salt spray); whether there are chemical media (acid mist, alkali, solvent vapour). The more these stack, the higher the category.
A practical rule: within 1 km of the coast, or 10 km but windward and unsheltered, treat as C5-M; inland general industrial as C4; a sheltered semi-exposed structure can be a step lower but never treated as interior.
3. The category sets thickness and inspection, not just paint
ISO 12944 gives recommended thickness by category and durability. C3 medium durability (7–15 years) is commonly 160 µm; C4 high durability (15–25 years) 200–240 µm; C5-M high durability often 280–320 µm; CX can exceed 350 µm.
Those are total dry film figures, not per coat. Splitting 320 µm into primer 80, intermediate 120 and topcoat 120 is a different thing from 'one coat at 320' — the latter will crack.
4. The cost of getting it wrong either way
Too low: the system fails within a few years and rework costs two to three times the original including surface preparation and lost production. Too high: material cost rises 30–50% for a life far beyond the structure's design life — pure waste.
The practical answer is to categorise by location, not one category for the whole project. Tank roof, platform grating, pipe rack underside and pump-house wall can each carry a different category and a different system. That way nothing is under-specified and nothing is gold-plated.