Selection

Concrete and steel cannot share one coating system: three physical differences

To a coating, steelwork and concrete are entirely different materials: one is dense, conductive and free of capillaries; the other is porous, alkaline and wet. Use one system for both and at least one side will fail.

1. Three physical differences

Porosity and moisture. Concrete is a capillary porous body and internal water migrates outward continuously. If the film has low permeability, vapour accumulates at the interface and pressures the coating off. Steel does not have this problem because it is not water-permeable.

Alkalinity. New concrete reaches pH 12–13 and holds it for months to years. Alkali saponifies oil and alkyd paints and degrades some epoxies. Steel has no alkalinity, which is why alkyd works on steel and not on concrete.

Strength and cracking. Concrete surface tensile strength is low, 1.5–3 MPa, and it shrinks and cracks. Coating adhesion is capped by substrate strength, and stiff thick-film systems crack along with the substrate.

2. What concrete needs

Penetrating primers first — low-viscosity epoxy, acrylic emulsion or silane — to seal pores rather than form a film. Film-forming primers on porous surfaces give false adhesion: they sit on the surface without penetrating.

Intermediate and topcoat by environment: epoxy for interior floors (abrasion resistant, easy to clean), acrylic or polyurethane for exterior walls (weathering and breathability), epoxy or polyurethane lining for water and wastewater tanks. The system must breathe, letting a little vapour through rather than trapping it.

3. Three things to confirm before application

Moisture content, generally below 6% before coating (4% for some systems). The calcium carbide method is accurate, the plastic sheet method rough. Coating over wet concrete guarantees blistering.

Curing age, generally 28 days or more so that alkali release and shrinkage are largely complete. Coating early to save schedule is a leading cause of rework.

Surface strength and flatness. Dusting or friable surfaces must be ground or scarified away, otherwise the paint bonds to laitance. On repaired areas, confirm compatibility between repair material and coating.

4. When the two can share

In one case only: a thick-film epoxy system indoors, dry and unexposed. Even then the primers should differ — anticorrosive primer for steel, penetrating sealer for concrete.

Sharing a topcoat is workable, for example polyurethane on both. Sharing the whole system is not. That distinction gets lost easily in quotations and site planning.

Need selection advice?

Tell us your substrate and service conditions

One-to-one coating consultancy: system design, quantity take-off and quotation.

Contact us
WhatsApp