PPG STEELGUARD FM 585
PPG STEELGUARD FM 585 is a Fire protection from PPG. This page groups model identity, system position and the data request entry so you can verify the full system before enquiring.
Key technical data
| Volume solids | 70 ± 3% |
|---|---|
| Dry film thickness | 200–700 µm (8.0–28.0 mil) per coat |
| Theoretical spreading rate | 1.00 m²/L |
| VOC | Maximum 20.0 g/kg |
| Density / specific gravity | 1.43 kg/L (11.93 lb/US gal) |
| Number of components | One-component |
| Thinner | 0 - 5% |
The technical content below is reproduced in English as published by the manufacturer; terms, grades and values follow the English original.
How this coating class protects
Fire protection coatings are fire safety products, not ordinary paints. Performance is fixed by type approval plus the certified system, and the relationship between thickness and fire rating is locked at testing time. It cannot be adjusted on site. That sets the selection logic: certification scope first, price second.
What to verify in the original TDS
These are checking criteria, not numeric commitments. Every figure follows the current original TDS.
- Approval type and scope of applicationThe substrate type, section factor and fire rating covered by the test report must match the actual project. Outside that scope the product is not valid.
- Thickness-to-rating tableThat table is part of the certification, not a recommendation. Work back from the required rating; do not estimate from experience.
- Intumescent or non-intumescentIntumescent is thin, looks better and suits internal steel; non-intumescent cementitious is thick and used outdoors, for hydrocarbon fires and in tunnels.
- Compatible primer and topcoatFire coatings place specific demands on the primer, whose expansion behaviour affects char formation.
Application control points
Follow the certified documents for preparation and primer
The primer type named in the report cannot be swapped; changing it steps outside the certification.
Measure every member and judge on the thinnest point
Beams, nodes, bolts and stiffeners vary widely. Acceptance is on the minimum, not the average.
Respect temperature and humidity limits
Intumescent coatings are sensitive to humidity and drying rate, and crack when applied thick. Build in coats with controlled intervals.
How to settle site disputes
Mixing thickness tables between manufacturers
Fire performance is a certified system result and cannot be transferred between similar products. Changing maker means new approval.
Using anti-corrosion paint as fire protection
The purposes differ. An anti-corrosion system provides no fire rating and will fail fire acceptance.
Common questions on this coating class
Can thickness be calculated in-house?
Does steel fire protection need a topcoat?
The above gives class-level technical requirements and judging methods. Specific values and systems follow the current original TDS and the project specification.
Place in the coating system
Primer–intermediate–topcoat layers and coat counts follow the exposure; DFT and curing conditions follow the original TDS and project specification.