MODEL DATA

Intertherm 7050

BrandAkzoNobel
ModelIntertherm 7050
CategoryThermal insulation

Intertherm 7050 is a Thermal insulation from AkzoNobel. This page groups model identity, system position and the data request entry so you can verify the full system before enquiring.

Key technical data

Volume solids100%
VOC0.00 lb/gal (0 g/L) US Environmental Protection Agency Method 24 0 g/
Density / specific gravity0.57 g/cm³ Note: the final density depends on the application method. Generally
Number of componentsTwo-component
ThinnerDo not thin
Mixing ratioAlways mix the whole unit of paint
Colour / appearancePink after uniform mixing

The technical content below is reproduced in English as published by the manufacturer; terms, grades and values follow the English original.

How this coating class protects

Thermal insulation coatings lower surface temperature or reduce heat loss through reflection, low conductivity or micro-void barriers. They are a thermal function layer, not a corrosion layer. Using them as anti-corrosion paint is the most common misuse. The correct position is above a complete anti-corrosion system, as an added function.

What to verify in the original TDS

These are checking criteria, not numeric commitments. Every figure follows the current original TDS.

  1. Mechanism (reflective or insulating) and suitable useReflective types work on solar radiation, insulating types on temperature difference. Tanks, pipes and roofs differ.
  2. Equivalent thermal resistance or conductivityCalculable thermal parameters are needed, otherwise design cannot be verified.
  3. Weathering and design lifeMost insulation coatings weather faster than a topcoat and need periodic renewal.
  4. Effect on inspection of the coating beneathA thick insulation layer hides corrosion, so inspection planning must allow for removal.

Application control points

Complete the anti-corrosion primer first

Where the insulation layer is not a vapour barrier, moisture condenses at the interface. The anti-corrosion system must be complete.

Uniformity drives performance

Reflective types work at the surface, insulating types through thickness. The application demands differ.

Surface cleanliness sets reflectivity

Dirt kills reflective performance quickly, so design for cleaning.

How to settle site disputes

Using insulation coating instead of a corrosion system

It gives no cathodic protection and no vapour barrier. The steel keeps corroding, invisibly.

Designing on advertised temperature differences

Measured differences depend heavily on substrate, colour and sun angle. Design from thermal parameters, not marketing figures.

Common questions on this coating class

Can insulation coating lower the product temperature in a tank?
It reduces surface temperature and heat gain, by an amount that depends on radiation and coating parameters. Run a heat balance; do not promise a fixed difference.
Does insulation coating need a topcoat?
Usually yes, for dirt and weather resistance. The topcoat changes reflectivity, so confirm compatibility with the insulation layer.

The above gives class-level technical requirements and judging methods. Specific values and systems follow the current original TDS and the project specification.

Place in the coating system

Primer–intermediate–topcoat layers and coat counts follow the exposure; DFT and curing conditions follow the original TDS and project specification.

Need the original TDS or a quote for this model?

Send the model, quantity, destination port and service conditions — we reply with a complete coating system, not a single can.

← AKZONOBEL / INTERNATIONAL Back to product catalog →
Need selection advice?

Tell us your substrate and service conditions

One-to-one coating consultancy: system design, quantity take-off and quotation.

Contact us
WhatsApp