175
175 is a Thermal insulation from Hempel. This page groups model identity, system position and the data request entry so you can verify the full system before enquiring.
Key technical data
| Volume solids | 87 ± 2% |
|---|---|
| Dry film thickness | 2000 µm |
| Theoretical spreading rate | 0.3 m²/L |
| VOC | 0 g/L (China) |
| Density / specific gravity | 0.4 kg/L |
| Number of components | Two-component |
| Colour / appearance | Window Grey 17700 |
The technical content below is reproduced in English as published by the manufacturer; terms, grades and values follow the English original.
How this coating class protects
Thermal insulation coatings lower surface temperature or reduce heat loss through reflection, low conductivity or micro-void barriers. They are a thermal function layer, not a corrosion layer. Using them as anti-corrosion paint is the most common misuse. The correct position is above a complete anti-corrosion system, as an added function.
What to verify in the original TDS
These are checking criteria, not numeric commitments. Every figure follows the current original TDS.
- Mechanism (reflective or insulating) and suitable useReflective types work on solar radiation, insulating types on temperature difference. Tanks, pipes and roofs differ.
- Equivalent thermal resistance or conductivityCalculable thermal parameters are needed, otherwise design cannot be verified.
- Weathering and design lifeMost insulation coatings weather faster than a topcoat and need periodic renewal.
- Effect on inspection of the coating beneathA thick insulation layer hides corrosion, so inspection planning must allow for removal.
Application control points
Complete the anti-corrosion primer first
Where the insulation layer is not a vapour barrier, moisture condenses at the interface. The anti-corrosion system must be complete.
Uniformity drives performance
Reflective types work at the surface, insulating types through thickness. The application demands differ.
Surface cleanliness sets reflectivity
Dirt kills reflective performance quickly, so design for cleaning.
How to settle site disputes
Using insulation coating instead of a corrosion system
It gives no cathodic protection and no vapour barrier. The steel keeps corroding, invisibly.
Designing on advertised temperature differences
Measured differences depend heavily on substrate, colour and sun angle. Design from thermal parameters, not marketing figures.
Common questions on this coating class
Can insulation coating lower the product temperature in a tank?
Does insulation coating need a topcoat?
The above gives class-level technical requirements and judging methods. Specific values and systems follow the current original TDS and the project specification.
Place in the coating system
Primer–intermediate–topcoat layers and coat counts follow the exposure; DFT and curing conditions follow the original TDS and project specification.
Need the original TDS or a quote for this model?
Send the model, quantity, destination port and service conditions — we reply with a complete coating system, not a single can.