Refurbishment system for port machinery

Coating system
| Layer | Material / system | DFT | Standard | |
|---|---|---|---|---|
| Primer | Epoxy zinc-rich primer (maintenance grade) | 60 μm | ISO 8501-1 St3/Sa2 | |
| Intermediate | MIO epoxy intermediate | 100 μm | ISO 12944-5 | |
| Topcoat | Polyurethane topcoat; wear-resistant epoxy on moving parts | 50 μm | ISO 12944-5 | |
| Total system DFT | ≈ 210 μm | |||
Maintenance coating on equipment in service, zone by zone without shutdown. Old film feathered, rust spots locally blasted to St3/Sa2.
Port container cranes run at high duty cycles; booms, travel gear and steelwork are exposed to salt spray and dust, leaving chalked and rusted paint. Refurbishment had to proceed zone by zone without full shutdown.
Old paint was feathered, rusted areas locally blast-cleaned to St3/Sa2, then the whole structure received epoxy zinc-rich primer, micaceous iron epoxy intermediate and polyurethane topcoat. Moving/abrasive parts used a wear-resistant epoxy finish.
Work followed equipment downtime windows with surrounding corrosion and fire protection. Humidity and salt contamination were controlled during curing; each zone was checked for DFT, adhesion and appearance.
The build-ups above are typical systems compiled from ISO 12944 and the relevant product technical data sheets; film thicknesses are reference values for the service conditions stated. For any specific project, the design specification, tender documents and the manufacturer's latest PDS govern. Actual performance depends on surface preparation grade, ambient conditions during application and recoat intervals.