Coating system for offshore wind towers

Coating system
| Layer | Material / system | DFT | Standard | |
|---|---|---|---|---|
| Primer | Epoxy zinc-rich or epoxy primer | 80 μm | ISO 12944-5 | |
| Intermediate | High-solids MIO epoxy | 160 μm | ISO 12944-5 | |
| Topcoat | Aliphatic polyurethane or polysiloxane | 80 μm | ISO 12944-5 | |
| Total system DFT | ≥ 320 μm | |||
Offshore tower exterior and transition piece: salt spray, UV and wind abrasion. Flanges and bolts reinforced separately.
Offshore wind towers face salt spray, wind-borne abrasion and UV exposure, with short maintenance windows and demanding recoat intervals. This project covers the tower exterior and foundation transition piece.
An epoxy zinc-rich or epoxy primer is used, with a high-solids micaceous iron epoxy intermediate and an aliphatic polyurethane or polysiloxane topcoat for colour and weatherability. Flanges and bolts receive local reinforcement.
All coating was completed in-factory; soft edge protection guarded the film during transport and erection. Site damage was repaired layer by layer with the same system, followed by holiday detection and DFT measurement.
The build-ups above are typical systems compiled from ISO 12944 and the relevant product technical data sheets; film thicknesses are reference values for the service conditions stated. For any specific project, the design specification, tender documents and the manufacturer's latest PDS govern. Actual performance depends on surface preparation grade, ambient conditions during application and recoat intervals.