MODEL DATA

471CN

BrandHempel
Model471CN
CategoryMIO epoxy intermediate

471CN is a MIO epoxy intermediate from Hempel. This page groups model identity, system position and the data request entry so you can verify the full system before enquiring.

Key technical data

Volume solids81 ± 2%
Dry film thickness200 µm
Theoretical spreading rate4.1 m²/L
VOC199 g/L (China)
Density / specific gravity2 kg/L
Number of componentsTwo-component
ThinnerHEMPEL's Thinner 08450
Colour / appearanceGrey-red MIO 12430

The technical content below is reproduced in English as published by the manufacturer; terms, grades and values follow the English original.

How this coating class protects

Micaceous iron oxide is a lamellar pigment. During application the flakes stack in layers and turn the path of water, oxygen and ions into a long, tortuous route. The value is not one more coat; it is that this coat separates the coats above and below while plugging pinholes and micro-defects. High build is its advantage over a topcoat.

What to verify in the original TDS

These are checking criteria, not numeric commitments. Every figure follows the current original TDS.

  1. Lamellar pigment content and flake sizeMIO loading drives barrier efficiency. A low-loaded product is essentially a coloured epoxy with an order of magnitude less barrier performance.
  2. Maximum DFT in a single coatHigh build is the whole point. If the data sheet caps single-coat thickness low, the formulation struggles with sagging or cracking and you will need multiple coats, which changes both schedule and cost.
  3. Overcoating windows to primer and topcoatIntermediate coats present a large exposed area for a long time; past the window they must be abraded. Window length drives the sequence plan.
  4. Presence of zinc or conductive filler for zinc-rich systemsOver a zinc-rich primer, a non-conductive intermediate cuts the cathodic protection path. This detail is easily missed in cross-brand systems.

Application control points

High build does not mean brushing it thick

Thick films need airless spray, the right tip and controlled pass speed. Rollering a thick film gives you a dry skin over uncured material, which then shrinks and cracks.

Stripe coat welds and edges first

The barrier value of an intermediate is most easily wasted at edges. Stripe coating before the full pass gets the edge thickness right.

Overcoating before full cure traps solvent

A thick intermediate releases solvent slowly. Topcoating at touch-dry seals solvent inside and blisters appear months later. Work to the hard-dry time in the TDS, not to the feel of the surface.

How to settle site disputes

Using the intermediate as filler

It is not a body filler. Using it to fill pits and weld spatter pushes local thickness far past design and concentrates cracking risk there. Substrate flatness belongs to the substrate stage.

Ignoring the conductive path in cross-brand systems

Zinc-rich primer plus another brand's intermediate, where the intermediate is a strong barrier without conductive filler, cuts the reach of cathodic protection. Inspection will not show it; the corrosion pattern years later will.

Common questions on this coating class

Can the intermediate coat be dropped?
In mild atmosphere below C3, a two-coat primer-plus-topcoat system is common practice. In C4, C5 and immersion service the intermediate carries most of the barrier duty; dropping it roughly halves service life.
MIO intermediate versus plain epoxy intermediate?
MIO is an epoxy with lamellar pigment: better barrier, better suited to high build. Plain epoxy intermediate focuses on intercoat adhesion and levelling. Choose by corrosivity category, not by price.

The above gives class-level technical requirements and judging methods. Specific values and systems follow the current original TDS and the project specification.

Place in the coating system

Typically used as an intermediate build coat adding barrier and total DFT; a topcoat is still required.

Need the original TDS or a quote for this model?

Send the model, quantity, destination port and service conditions — we reply with a complete coating system, not a single can.

← HEMPEL Back to product catalog →
Need selection advice?

Tell us your substrate and service conditions

One-to-one coating consultancy: system design, quantity take-off and quotation.

Contact us
WhatsApp